<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-18 03-35-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 51 dBuV YLEX
Pilot RDS Phase Difference
7.5 kHz 2.5 kHz 64 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 11 kHz 19040 0,0840
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,1 dBr 1,72 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 3:35, 18.12.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 11 kHz MIN: 10 kHz % above 76 kHz: 0,0840 Acquired: 2025/12/18 3.33.59 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,7 dBr MIN: -0,1 dBr AVE: 1,72 dBr % above 12,2 dBr: 0,0 Last value: -0,1 dBr (2025/12/18 3.33.59) 03.20 03.22 03.24 03.26 03.28 03.30 03.32 0 2 4 Pm [dBr]